AAAC


Application

AAAC is mainly used as bare overhead transmission cable and as primary and secondary distribution cable. It is also suitable for laying across basins, rivers and valleys where special geographical feature exist.

Standard

Basic design to BS 3242 / BS EN 50182 / IEC 61089 / ASTM B 399/B 399M / DIN 48201 -6 standards

Construction

AAAC cable by consists of aluminum alloy wires. The aluminum alloy wires are concentrically stranded.

aaac-11.png

Technical Properties

Composition

Composition Final modulus of elasticity

Final modulus
  of elasticity
  Mpa

Composition

Composition Final modulus of elasticity

Final modulus
  of elasticity
  Mpa


Mpa

°C


Mpa

°C

7

62000

23X10-6

61

54000

23X10-6

19

60000

23X10-6

91

52000

23X10-6

37

57000

23X10-6

127

50500

23X10-6

 

Operating Temperature:

Ambient temperature of 50° C, max permissible continuous operating temperature of conductor shall not exceed 80°C.

Packing

Steel/wooden reel, wooden reel or steel reel

 

 

All Aluminum Alloy Conductor (AAAC) Parameter:

 

IEC 61089

Code

Nominal Area

Stranding

Overall Diameter

Weight

Rated Strength

Electrical Resistance

Current Rating*


mm2

No.×mm

mm

kg/km

KN

Ω/Km

A

16

18.4

7/1.83

5.49

50.4

5.43

1.7896

86

25

28.8

7/2.29

6.87

78.7

8.49

1.1453

113

40

46

7/2.89

8.67

125.9

13.58

0.7158

151

63

72.5

7/3.36

10.89

198.3

21.39

0.4545

200

100

115

19/2.78

13.9

316.3

33.95

0.2877

266

125

144

19/3.10

15.5

395.4

42.44

0.2302

305

160

184

19/3.51

17.55

506.1

54.32

0.1798

355

200

230

19/3.93

19.65

632.7

67.91

0.1439

407

250

288

19/4.39

21.95

790.8

84.88

0.1151

466

315

363

37/3.53

24.71

998.9

106.95

0.0916

535

400

460

37/3.98

27.86

1268.4

135.81

0.0721

618

450

518

37/4.22

29.54

1426.9

152.79

0.0641

663

500

575

37/4.45

31.15

1585.5

169.76

0.0577

706

560

645

61/3.67

33.03

1778.4

190.14

0.0516

755

630

725

61/3.89

35.01

2000.7

213.9

0.0458

809

710

817

61/4.13

37.17

2254.8

241.07

0.0407

866

800

921

61/4.38

39.42

2540.6

271.62

0.0361

928

900*

1036

91/3.81

41.91

2861.1

305.58

0.0321

992

1000*

1151

91/4.01

44.11

3179

339.53

0.0289

1051

1120*

1289

91/4.25

46.75

3560.5

380.27

0.0258

1118

1250*

1439

91/4.49

49.39

3973.7

424.41

0.0231

1185

 

 

 

 

 

 

 

 

 

 

Din 48201 Part 6

Nominal Area

Stranding

Overall Diameter

Weight

Rated Strength

Electrical Resistance

Current Rating*

Nominal

Theoretical

mm2

mm2

No.×mm

mm

kg/km

KN

Ω/Km

A

16

15.89

7/1.70

5.1

43

4.44

2.0742

78

25

24.25

7/2.10

6.3

66

6.77

1.3593

102

35

34.36

7/2.50

7.5

94

9.6

0.9591

126

50

49.48

7/3.00

9

135

13.82

0.666

158

50

48.35

19/1.80

9

133

13.5

0.6849

156

70

65.81

19/2.10

10.5

181

18.38

0.5032

189

95

93.27

19/2.50

12.5

256

26.05

0.3551

234

120

116.99

19/2.80

14

322

32.68

0.2831

269

150

147.11

37/2.25

15.8

406

41.09

0.2256

309

185

181.62

37/2.50

17.5

500

50.73

0.1828

352

240

242.54

61/2.25

20.3

670

67.74

0.1371

420

300

299.43

61/2.50

22.5

827

83.63

0.111

477

400

400.14

61/2.89

26

1104

111.76

0.0831

568

500

499.83

61/3.23

29.1

1379

139.6

0.0665

649

625*

626.2

91/2.96

32.6

1732

174.9

0.0531

742

800*

802.09

91/3.35

36.9

2218

224.02

0.0415

857

1000*

999.71

91/3.74

41.1

2767

279.22

0.0333

971



AAAC