N2XRH LSZH Armoured Power Cables

Construction:
Stranded Copper Conductor, XLPE Insulation,LZSH Bedding,Steel/AL Wire Armour, LZSH Sheathed

Application:
Power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. 
Technical Data:
Conductor:  1.5 - 16 mm2 in solid Conductor, Class 1
16-800 in Strand Conductor, Class 2
Working voltage:0.6/1KV
Test Voltage:  4000V
Working Temperature:-5-90 º C
Bending radius 1.5mm² to 16mm²: 6 x overall diameter
25mm² and above: 8 x overall diameter
Standard:
IEC60502-1,BS 6724
Flame retardant IEC60332 part 1, BS4066 part 1
Halogen free IEC 60754, EN 50267
Smoke density IEC 61034, EN50268
Cable Parameter:
Single-core LSZH Armoured Power Cables

Nominal Cross-sectional Area

Strand Type

Nominal Insulation Thickness

Nominal Bedding Thickness

Nominal Alum Wire Armor dia.

Nominal Sheath Thickness

Approx. Overall Diameter

Aprrox Weight

mm²

No./mm

mm

mm

mm

mm

mm

kg/km

1x50

19/1.78

1

0.8

0.9

1.5

17.5

800

1x70

19/2.14

1.1

0.8

1.25

1.5

20.2

990

1x95

19/2.52

1.1

0.8

1.25

1.6

22.3

1280

1x120

37/2.03

1.2

0.8

1.25

1.6

24.2

1550

1x150

37/2.25

1.4

1

1.6

1.7

27.4

1900

1x185

37/2.52

1.6

1

1.6

1.8

30

2320

1x240

61/2.25

1.7

1

1.6

1.8

32.8

2930

1x300

61/2.52

1.8

1

1.6

1.9

35.6

3580

1x400

61/2.85

2

1.2

2

2

40.5

4600

1x500

61/3.20

2.2

1.2

2

2.1

44.2

5680

1x630

127/2.52

2.4

1.2

2

2.2

48.8

7160

1x800

127/2.85

2.6

1.4

2.5

2.4

55.4

9315

1x1000

127/3.20

2.8

1.4

2.5

2.5

60.6

11490


Three Core LSZH Armoured Cable

Nominal Cross-sectional Area

Strand Type

Nominal Insulation Thickness

Nominal Bedding Thickness

Nominal Steel Wire Armor dia.

Nominal Sheath Thickness

Approx. Overall Diameter

Aprrox Weight

mm²

No./mm

mm

mm

mm

mm

mm

kg/km

3x1.5

7/0.53

0.6

0.8

0.9

1.3

12.6

340

3x2.5

7/0.67

0.7

0.8

0.9

1.4

14.1

408

3x4

7/0.85

0.7

0.8

0.9

1.4

15.3

498

3x6

7/1.04

0.7

0.8

0.9

1.4

16.6

600

3x10

7/1.35

0.7

0.8

1.25

1.5

19.5

915

3x16

7/1.70

0.7

0.8

1.25

1.6

21.6

1130

3x25

7/2.14

0.9

1

1.6

1.7

26.7

1710

3x25*

7/2.14

0.9

1

1.6

1.7

23.6

1710

3x35

7/2.52

0.9

1

1.6

1.8

29.4

2100

3x35*

7/2.52

0.9

1

1.6

1.8

25.7

2100

3x50*

19/1.78

1

1

1.6

1.8

28.5

2450

3x70*

19/2.14

1.1

1

1.6

1.9

32.2

3120

3x95*

19/2.52

1.1

1.2

2

2.1

37

4310

3x120*

37/2.03

1.2

1.2

2

2.2

40.4

5160

3x150*

37/2.25

1.4

1.4

2.5

2.3

45.5

7160

3x185*

37/2.52

1.6

1.4

2.5

2.4

49.8

8600

3x240*

61/2.25

1.7

1.4

2.5

2.6

55.1

10755

3x300*

61/2.52

1.8

1.6

2.5

2.7

60.2

13080

3x400*

61/2.85

2

1.6

2.5

2.9

66.6

15810

Four Core cable:

Nominal Cross-sectional Area

Strand Type

Nominal Insulation Thickness

Nominal Bedding Thickness

Nominal Steel Wire Armor dia.

Nominal Sheath Thickness

Approx. Overall Diameter

Aprrox Weight

mm²

No./mm

mm

mm

mm

mm

mm

kg/km

4x1.5

7/0.53

0.7

0.8

0.9

1.4

13.3

390

4x2.5

7/0.67

0.7

0.8

0.9

1.4

15

470

4x4

7/0.85

0.7

0.8

0.9

1.4

16.4

580

4x6

7/1.04

0.7

0.8

1.25

1.5

18.7

805

4x10

7/1.35

0.7

0.8

1.25

1.5

21.1

1090

4x16

7/1.70

0.7

0.8

1.25

1.6

23.4

1320

4x25

7/2.14

0.9

1

1.6

1.7

28.9

1840

4x25*

7/2.14

0.9

1

1.6

1.7

26.1

1840

4x35

7/2.52

0.9

1

1.6

1.8

31.9

2310

4x35*

7/2.52

0.9

1

1.6

1.8

28.6

2310

4x50*

19/1.78

1

1

1.6

1.9

32

2970

4x70*

19/2.14

1.1

1.2

2

2.1

37.7

4240

4x95*

19/2.52

1.1

1.2

2

2.2

41.7

5400

4x120*

37/2.03

1.2

1.4

2.5

2.3

47.1

7000

4x150*

37/2.25

1.4

1.4

2.5

2.4

51.4

8350

4x185*

37/2.52

1.6

1.4

2.5

2.6

56.6

10130

4x240*

61/2.25

1.7

1.6

2.5

2.7

63

12840

4x300*

61/2.52

1.8

1.6

2.5

2.9

68.8

15530

4x400*

61/2.85

2

1.8

3.15

3.2

78.1

19950


Five Core Cable

Nominal Cross-sectional Area

Strand Type

Nominal Insulation Thickness

Nominal Bedding Thickness

Nominal Steel Wire Armor dia.

Nominal Sheath Thickness

Approx. Overall Diameter

Aprrox Weight

mm²

No./mm

mm

mm

mm

mm

mm

kg/km

5x1.5

7/0.53

0.6

0.8

0.9

1.4

14.3

430

5x2.5

7/0.67

0.7

0.8

0.9

1.4

16.1

545

5x4

7/0.85

0.7

0.8

0.9

1.5

17.8

680

5x6

7/1.04

0.7

0.8

1.25

1.5

20

840

5x10

7/1.35

0.7

0.8

1.25

1.6

22.9

1105

5x16

7/1.70

0.7

1

1.6

1.7

26.6

1450

5x25

7/2.14

0.9

1

1.6

1.8

31.5

2245

5x35

7/2.52

0.9

1

1.6

1.9

34.8

2840

5x50

19/1.78

1

1.2

2

2

40.4

3895

5x70

19/2.14

1.1

1.2

2

2.2

46.3

5145



N2XRH LSZH Armoured Power Cables